ALFA LAVAL AC65 Refrigerant Brazed Plate Heat Exchanger Price Low
Alfa Laval AC65 / ACH65 is a Brazed Plate Heat Exchanger BPHE for heat pump systems. Optimized for R290 heat exchanger for residential applications, it delivers reliable thermal performance in residential heating, domestic hot water, and HVAC cooling systems.
Alfa Laval AC65 BPHE details
Alfa Plate Heat Exchanger Model
Alfa Laval AC65
Keyword
Brazed Plate Heat Exchanger Chiller
Plate Quantity Range
10–120 Plates
Material
SS304/SS316/COPPER
Capacity
Up to 150 kW (Depending on operating conditions and plate configuration)
Connection Size
1″ BSP (Typical)
Maximum Flow Rate
Up to 11 m³/h
Compatible Refrigerants
R290 (Propane), R32, R410A, HFC, HFO and Natural Refrigerants
Applications
Heat Pump, Chiller, Air Conditioning, Refrigeration, Condenser, Evaporator
DESCRIPTION
The Alfa Laval AC65 / ACH65 is a Brazed Plate Type Heat Exchanger for efficient heat transfer in residential and light commercial heating and cooling systems.
As an R290 heat exchanger for residential applications, it is suitable for modern low GWP refrigerant systems that require reliable thermal performance.
Copper Brazed Heat Exchanger design supports making heat pumps more efficient and sustainable by improving heat transfer efficiency in energy saving systems.
Engineered as a BPHE optimized for residential heat pumps, this model is widely used in residential heat pumps, hot water systems, and hydronic heating applications.
The AC65 Copper Plate Heat Exchanger is commonly selected for air conditioning and heat pump solutions across residential and commercial installations.
At Senovis Brazed Plate Heat Exchanger Manufacturers , we manufacture Brazed Plate Heat Exchanger Price low solutions for Alfa Laval AC series plate heat exchangers, supporting OEMs, distributors, and maintenance professionals worldwide.
specification
| MODEL | Alfa Laval AC65 |
| Keyword | Brazed Plate Heat Exchanger, Heat Pump, R290 Heat Pump, HVAC, Chiller, Refrigeration |
| Plate Number | 10–120 Plates |
| Thickness A (mm) | 11.5 + (1.38 × n) mm (n = Number of Plates) |
| Dimension LWH (mm) | 535 × 120.5 × A mm |
| Center Distance (mm) | 60 mm / 476 mm |
| Weight (kg) | 2.1 + (0.14 × n) kg (Excluding Connections) |
| Volume (L) Q1Q2 Side / Q3Q4 Side | 0.088 L / 0.046 L per channel |
| Designed Pressure | Max. 32 bar (AC65) / Max. 45 bar (ACH65) |
| Designed Temperature | -196°C ~ +225°C (Pressure-temperature rating depends on version) |
| Plate Materials | Stainless Steel 316L / Copper Brazing |
| Capacity | |
Installation Guidelines for Alfa Laval AC65 in Heat Pump
Alfa Laval AC65 / ACH65 Installation Notes
The AC65/ACH65 is a common choice for evaporators and condensers in residential and commercial heat pump systems. Getting the installation right matters more than people think a heat exchanger that’s correctly sized on paper can still underperform badly if the piping around it is wrong.
Orientation and Flow Direction
Always follow the port orientation and flow direction shown in the manual don’t guess based on how it looks like it should connect. Reversing the flow path, especially on the evaporator side, throws off refrigerant distribution and drops heat transfer efficiency, sometimes significantly.
If you’re running multiple units in parallel, keep the piping symmetrical on both sides. Asymmetric piping is one of the most common causes of uneven flow between parallel exchangers one unit ends up doing more work than the others, and you get inconsistent performance that’s hard to diagnose later.
Flow Rate and Pressure Drop
Stay within the designed flow range. Run it too low and you’ll see the evaporating temperature drop, COP suffer, and heat transfer become unstable — sometimes with audible flow noise as a warning sign.
When you’re calculating system pressure drop, don’t just look at the heat exchanger spec sheet. Pumps, filters, check valves, solenoid valves — they all add up, and skipping this step is a common reason systems come in underperforming after commissioning.
Keep the System Clean
Brazed plates don’t tolerate debris well the channels are narrow, and once something lodges in there, it’s not coming out easily. Flush the piping thoroughly before commissioning to clear welding slag, metal shavings, and general construction debris.
A filter installed just ahead of the heat exchanger is cheap insurance against blockage. Skipping it is a false economy.
Freeze Protection and Air Venting
If it’s running as an evaporator, make sure freeze protection is in place for shutdown periods or low-temperature conditions a frozen plate exchanger is an expensive mistake.
Don’t forget air venting on the water/glycol side. Trapped air causes flow instability, hurts heat transfer, and is a common source of the knocking or gurgling noise customers complain about post-installation.
Support and Vibration
The AC65 is compact, but that doesn’t mean it can carry piping weight or stress on its ports. Support the piping independently so the connections aren’t taking the load.
Where there’s compressor pulsation, pump vibration, or thermal expansion in play, use flexible connectors and properly placed supports. This isn’t optional in systems with reciprocating compressors , the fatigue stress on brazed joints adds up over time.
Before You Start Up, Check:
- Flow direction matches the design
- Valves are in the correct position
- Filters are installed
- Piping has been flushed and cleaned
- Air has been fully vented
- Pressure testing is complete and passed
- Insulation is in place where specified
For systems using R290 or other flammable refrigerants, leak detection, ventilation, and electrical safety need to meet local code and system-specific safety requirements — this isn’t something to shortcut regardless of installer experience level.
Actual Product Details



Compatible Alfa Laval AC Series Models
Compatible replacement for:
- Alfa Laval AC16
- Alfa Laval AC20
- Alfa Laval AC24
- Alfa Laval AC30
- Alfa Laval AC50
- Alfa Laval AC60
- Alfa Laval AC65
- Alfa Laval AC72
- Alfa Laval AC73
- Alfa Laval AC74
- Alfa Laval AC112
- Alfa Laval AC220
- Alfa Laval AC230
- Alfa Laval AC232
- Alfa Laval AC240
- Alfa Laval AC500
- Alfa Laval AC502
- Alfa Laval AC540
- Alfa Laval AC900
- Alfa Laval AC1000
- Need another AC model? Contact SENOVIS for a fast quotation and technical support.