Compatible Alfa Laval AC50 brazed plate heat exchanger for commercial HVAC and heat pump applications
Reliable compatible AC50 plate heat exchanger for heating and cooling systems.

10 20 30 Plates AC50 Alfa Laval Brazed Plate Heat Exchanger HVAC Cooling

Alfa Laval AC50 is a Heat Exchanger Brazed Plate for HVAC, air conditioning, refrigeration, and heat pump systems. It provides efficient heat transfer for commercial cooling systems and industrial refrigeration. Our Alfa Laval AC50 compatible replacement offers reliable performance, fast quotations, and worldwide shipping.

Alfa Laval AC50 BPHE details

Alfa Plate Heat Exchanger Model

Alfa Laval AC50

Keyword

Heat Exchanger Brazed Plate

Plate Quantity Range

10–120 Plates

Material

SS304/SS316/COPPER

Capacity

Up to 70 kW

Connection Size

1″ BSP (Typical)

Maximum Flow Rate

Up to 8.8 m³/h

Refrigerants

R32, R134a, R407C, R410A, HFC, HFO and Natural Refrigerants

Applications

Heat Pump, Air Conditioning, Chiller, Refrigeration, Condenser, Evaporator, Heat Recovery

DESCRIPTION

The AC502DQ / ACH502DQ / ACK502DQ is a Industrial Brazed Plate Heat Exchangers for efficient heat transfer in demanding cooling and refrigeration systems.

The Alfa Laval plate heat exchanger AC50-80HX conn.4xR1 1/4 configuration is commonly specified for equipment replacement, OEM manufacturing, and system maintenance where reliable thermal performance is required.

Compared with the Alfa Laval AC16 / ACH16, the AC50 Refrigerant Brazed Plate Heat Exchanger is suitable for applications requiring greater heat transfer capacity while maintaining a compact installation footprint.

This model is widely used in Commercial refrigeration, including condensing units, cold storage systems, refrigeration equipment, and process cooling applications.

At Senovis PHE, we manufacture replacement brazed plate heat exchangers for global OEMs, distributors, and maintenance professionals, providing dependable thermal solutions for a wide range of refrigeration and HVAC applications.

specification

MODELAlfa Laval AC50
KeywordBrazed Plate Heat Exchanger, Heat Pump, Chiller, HVAC, Air Conditioning, Refrigeration
Plate Number10–120 Plates
Thickness A (mm)10 + (2.40 × n) mm (n = Number of Plates)
Dimension LWH (mm)526 × 111 × A mm
Center Distance (mm)50 mm / 437 mm
Weight (kg)1.8 + (0.23 × n) kg (Excluding Connections)
Volume (L) Q1Q2 Side / Q3Q4 Side0.080 L / 0.080 L per channel
Designed PressureMax. 32 bar (AC50) / Max. 45 bar (ACH50)
Designed Temperature-196°C ~ +225°C (Depending on pressure rating)
Plate MaterialsStainless Steel 316L / Copper Brazing
CapacityUp to 120 kW (Depending on operating conditions and plate configuration)

How Does the AC50 Handle Condensing Pressure Fluctuations?

The AC50 itself responds fast to pressure changes — brazed plate construction means low thermal mass, so it tracks condensing-side swings almost in real time. But whether your system stays stable when condensing pressure fluctuates has much less to do with the heat exchanger and much more to do with how the rest of the circuit is set up.

What actually happens on the condensing side

When condensing pressure climbs, you typically see the condensing temperature rise, subcooling drop, the compressor working against a higher pressure ratio, and COP falling off. That’s just refrigeration cycle behavior — it happens whether you’re running an AC50 or anything else.

Where the AC50 fits in

For moderate, normal fluctuations, the AC50 handles it without issue — it’s built for high-pressure AC and refrigeration duty, so this is well within its operating envelope.

If fluctuations get frequent or severe, the plate exchanger usually isn’t where the problem starts. It’s more often the compressor cycling, the expansion valve struggling to track a moving target, or uneven refrigerant distribution feeding into it. Large swings can leave you with unstable liquid supply and inconsistent subcooling, which drags cooling capacity and COP down — but that’s a system symptom, not an AC50 limitation.

What matters for a stable install

The AC50 gives you fast thermal response and a compact footprint, which actually helps in systems where condensing pressure isn’t perfectly steady. But getting stable output still comes down to matching the exchanger properly to the rest of the system:

  • Condenser sized correctly for the load
  • Refrigerant charge dialed in
  • Expansion valve settings suited to your operating range
  • Steady air-side or water-side cooling conditions feeding the condenser

If you’re seeing excessive fluctuation

Check the condenser first — airflow or water flow rate, compressor loading behavior, and whether the AC50’s pressure rating, connection type, and refrigerant compatibility actually match your application. Nine times out of ten it’s a control or sizing issue upstream, not the plate exchanger.

Bottom line: reliable performance under fluctuating conditions comes from picking the right heat exchanger and getting the control strategy right around it — not from the exchanger carrying the load on its own.

Actual Product Details

Production line for compatible Alfa Laval AC50 brazed plate heat exchangers
Precision manufacturing of compatible AC50 plate heat exchangers.
Manufacturing inspection of compatible Alfa Laval AC50 plate heat exchanger
Careful inspection helps ensure dependable product quality.
Export-ready compatible Alfa Laval AC50 brazed plate heat exchanger in protective packaging
Secure export packaging for worldwide shipment.

Compatible Alfa Laval AC Series Models

Compatible replacement for:

  • Alfa Laval AC16
  • Alfa Laval AC20
  • Alfa Laval AC24
  • Alfa Laval AC30
  • Alfa Laval AC50
  • Alfa Laval AC60
  • Alfa Laval AC65
  • Alfa Laval AC72
  • Alfa Laval AC73
  • Alfa Laval AC74
  • Alfa Laval AC112
  • Alfa Laval AC220
  • Alfa Laval AC230
  • Alfa Laval AC232
  • Alfa Laval AC240
  • Alfa Laval AC500
  • Alfa Laval AC502
  • Alfa Laval AC540
  • Alfa Laval AC900
  • Alfa Laval AC1000
  • Need another AC model? Contact SENOVIS for a fast quotation and technical support.

faq