Brazed PHE Alfa Laval CB110 16l 20l 24l 30m 38h 46h 46l 54m 76h 90h 110h
BPHE Model
Alfa Laval CB110 / 16l / 20l / 24l / 30m / 38h / 46h / 46l / 54m / 76h / 90h / 110h
Payment Method
T/T, L/C, Western Union, MoneyGram, PayPal, Credit Card
Stock & Shipment
In stock | Fast delivery
Minimum Order Quantity
1 pieces
Price
Negotiation
Packaging Details
Standard Export Packaging
Alfa Laval CB110 BPHE details
Brass Plate Heat Exchanger Model
Alfa Laval CB110 Stainless Steel Brazed Plate Heat Exchanger
Keyword
Refrigeration Plate Heat Exchanger
Plate Quantity Range
10 – 240 Plates
Material
SS304/SS316/COPPER
Capacity
50 kW – 900 kW (Max flow rate: 51 m³/h)
Other Brazed Plate
alfa laval CB110 / alfa laval cb110 / alfa laval cb110-20l / alfa laval cb110 38h / alfa laval cb110-30m / alfa laval cb110 76h / alfa laval cb110 90h / alfa laval cb110aq 54m / alfa laval cb110-110h / alfa laval cb110-46l / alfa laval cb110 24l / alfa laval cb110 20l / alfa laval cb110 16l / alfa laval cb110-46h
DESCRIPTION
The Alfa Laval CB110 is a large capacity brazed plate heat exchanger designed for high-demand heating, cooling, and industrial process applications where compact footprint and reliable thermal performance are both critical. The CB110 series covers a wide range of plate configurations to meet varying flow rate and heat load requirements , including the CB110-16L, CB110-20L, CB110-24L, CB110-30M, CB110-38H, CB110-46H, CB110-46L, CB110-54M, CB110-76H, CB110-90H, and CB110-110H — as well as specialized variants such as the CB110AQ-54M for aquatic and process side applications. Built with 316L stainless steel plates and copper brazing, the Alfa Laval CB110 is widely specified for district heating substations, industrial chillers, heat pump systems, and large HVAC installations where higher flow capacity and thermal output are required.
specification
| Brazed Plate Heat Exchanger Chiller Replacemnet | Nickel Brazed Plate Heat Exchanger |
| Keyword | Alfa Laval Nickel Brazed Heat Exchanger |
| Plate Number | 10 – 240 |
| Thickness A (mm) | 15 + 2.56 x n (e.g., 30 plates: 91.8 mm / 110 plates: 296.6 mm) |
| Dimension LWH (mm) | (15 + 2.56 x n) x 191 x 616 |
| Center Distance (mm) | Vertical: 519 / Horizontal: 92 |
| Weight (kg) | 4.82 + 0.35 x n (e.g., 30 plates: 15.32 kg / 110 plates: 43.32 kg) |
| Volume (L) Q1Q2 Side / Q3Q4 Side | Channel volume: 0.21 L (Total: approx. 0.21 x n/2 per side) |
| Designed Pressure | 26 – 30 bar (Depending on pressure vessel standards) |
| Designed Temperature | -196°C ~ +225°C |
| Plate Materials | Stainless Steel 316L / Copper Brazing |
| Capacity | 50 kW - 900 kW (Max flow rate: 51 m³/h) |
Alfa Laval CB110 Maintenance & Service Guide
The Alfa Laval CB110 brazed plate heat exchanger is designed for long-term operation with relatively low maintenance requirements. Since the unit uses a fully brazed construction, there are no gaskets to replace during normal service. In most HVAC, hydronic heating, and industrial cooling systems, maintenance mainly focuses on monitoring operating conditions, controlling water quality, and cleaning the unit when performance begins to decline.
Routine Operational Checks
Monitor Pressure Drop and Temperature Performance
Regularly check the inlet and outlet temperatures as well as the pressure differential across the CB110. A gradual increase in pressure drop or reduced heat transfer efficiency usually indicates internal fouling, scaling, or partial blockage inside the plate channels.
In practical operation, many technicians prefer to schedule cleaning based on actual performance data rather than fixed maintenance intervals. This helps reduce unnecessary downtime while keeping the system operating efficiently.
Inspect Connections and External Components
During routine inspections, check:
- Pipe connections
- Threaded fittings and flanges
- Valves and support brackets
- External corrosion or rust marks
- Small leaks or seepage around connections
Loose fittings, vibration wear, or minor leakage should be addressed early to avoid damage to nearby pipework or insulation.
System Level Maintenance
Water Quality Control
For closed-loop heating and cooling systems, stable water quality is one of the most important factors affecting CB110 service life. Poor water conditions can lead to internal scaling, corrosion, and reduced thermal performance over time.
Key parameters to monitor include:
- Water hardness
- pH value
- Chloride content
- Suspended solids
Water treatment filters and bypass filters should also be cleaned or replaced according to the system maintenance schedule.
Open Systems and Cooling Tower Maintenance
For cooling tower or open-loop systems, contamination from the system side is often the main cause of fouling inside the heat exchanger.
Routine maintenance may include:
- Cleaning cooling tower fill media
- Removing sludge and biological buildup
- Controlling algae and bacterial growth
Keeping the circulating water clean is usually far more cost-effective than dealing with severe internal fouling later.
When to Clean or Service the CB110
Performance-Based Indicators
Chemical cleaning is generally recommended when:
- Pressure drop rises about 20–30% above the original operating value
- Outlet temperature can no longer meet design conditions
- Heat transfer efficiency drops noticeably
In real applications, these operating changes are often more useful than relying only on calendar-based service intervals.
Chemical Cleaning
Chemical circulation cleaning is the standard cleaning method for the CB110. Cleaning agents must be compatible with both 316L stainless steel plates and copper brazing material.
Using overly aggressive chemicals may damage the brazing joints or accelerate internal corrosion, especially in older units.
Physical Blockage
If severe blockage occurs, backflushing may help remove loose debris or sediment. However, the CB110 is a non-dismantlable brazed plate heat exchanger, so internal mechanical disassembly is generally not recommended outside of factory or certified service conditions.
Attempting to force open the brazed structure will permanently damage the unit.
Long-Term Operating Recommendations
Invest in Water Quality First
In long-term operation, proper water treatment usually extends service life more effectively than frequent cleaning.
Common recommendations include:
- Closed-loop circulation design
- Corrosion inhibitor dosing
- Softened or deionized water where required
These measures help reduce scaling and internal corrosion inside the plate channels.
Install Pressure and Temperature Instrumentation
Installing pressure gauges and temperature sensors at both inlet and outlet connections makes it easier to monitor long-term operating trends.
This allows maintenance teams to:
- Detect fouling early
- Compare operating performance over time
- Schedule cleaning before major efficiency loss occurs
- Reduce unexpected downtime
For most CB110 systems, regular monitoring and stable water quality are the most effective ways to maintain reliable long-term heat exchanger performance.
Direct Contact Channels:
Reduce your maintenance costs with SENOVIS PHE ! As a specialized factory for GPHE, BPHE, plates, and gaskets, we offer 100% interchangeable solutions for Alfa Laval, APV, Tranter, Sondex, GEA, and more. Click “Contact Us” to request a quick quote and premium catalog now!